Product Description:
Sorensen XFR150-8 1200 W, 0-150 V, 0-8 A
Performance Characteristics of the XFR150-8
| Form Factor |
Benchtop |
| No. of Outputs |
1 o/p |
| Range programming modes |
Auto |
| Output 1 Max. power |
1200 Watts |
| Output 1/Range 1 Max. Current |
8 A (0 V to 150 V) |
| Voltage Programming Accy Output1/Range1 |
1.0666E-02 % |
| Current Programming Accy Output1/Range1 |
0.011 % |
| Voltage Readback Accy Output1/Range1 |
0.01 % |
| Current Readback Accy Output1/Range1 |
0.01 % |
| Voltage Ripple and Noise |
7 mV |
| Current Ripple and Noise |
3 mA |
| Load Regulation, Voltage |
35 mV |
| Load Regulation, Current |
6.6 mA |
| Line Regulation, Voltage |
17 mV |
| Line Regulation, Current |
2.8 mA |
| Transient Response Time |
3 ms |
| Remote Sensing Measurement |
Yes |
| Multiple Unit Combinations |
Parallel,Series |
| Overvoltage Protection |
Yes |
| Overcurrent Protection |
Yes |
| Over-temperature Protection |
Yes |
| Local Lockout |
Yes |
| Self test |
No |
Programmability/Connectivity of the XFR150-8
| User Interface |
Proprietary
|
| Ports to Peripheral Devices |
GPIB
|
XFR150-8 Compliance
| CE Compliance |
Compliant
|
| UL Compliance |
Not compliant
|
XFR150-8 Power Requirements
| Input Power |
Universal (Auto Sense and Switch) |